Home › California › CA homeowner hub › California contractor license classifications explained (A, B, B-2, C and D)

California homeowner guide · Reviewed 2026-11-14 against CSLB publications · By David Linda, Founder

California contractor license classifications explained (A, B, B-2, C and D)

Quick answer: CSLB issues four groups of licenses. A is General Engineering, B is General Building, B-2 is Residential Remodeling, and C covers specialty trades such as C-10 Electrical, C-36 Plumbing and C-39 Roofing, with C-61 Limited Specialty split into D subcategories. Hire a contractor whose classification covers your job. A B general contractor can take a single-trade job only if it holds that specialty or subcontracts it, unless the job is framing or carpentry.

On this page: How to read a classification · All CSLB classifications in plain English · The B general contractor rule · B-2 Residential Remodeling · Heat pumps, solar and batteries · FAQ · Sources

How to read a classification

On the CSLB License Check and on every HomeProFax California profile, classifications appear as codes like "B", "C-10" or "C-61/D-49". A contractor can hold several. The classification has to cover the work in your contract, not just the company's general line of business. Use the classification-by-job tool to look it up by project.

All CSLB classifications in plain English

ClassWhat it covers
AGeneral Engineering
Large fixed works that need engineering know-how: grading, roads, sewers, pipelines, bridges, dams, utilities and similar site and infrastructure work.
BGeneral Building
Structures for people, animals or property. Can take a whole job that involves framing or carpentry, or at least two unrelated trades; must hold the right specialty or hire a licensed specialty contractor otherwise.
B-2Residential Remodeling
Improvements to an existing wood-frame home when the single contract involves at least three unrelated trades (for example drywall, flooring and painting). No structural changes to load-bearing parts and no new or extended electrical, plumbing or mechanical systems unless properly licensed or subcontracted.
C-2Insulation and Acoustical
Insulation and sound-control materials in walls, ceilings, attics and floors.
C-4Boiler, Hot-Water Heating and Steam Fitting
Boilers, hot-water and steam heating systems, including related piping and controls.
C-5Framing and Rough Carpentry
Framing, form work, subfloors, roof decking, exterior stairs and railings, sheathing and similar rough carpentry.
C-6Cabinet, Millwork and Finish Carpentry
Cabinets, built-ins, trim, doors, windows set in finished openings and other finish carpentry.
C-7Low Voltage Systems
Communications, data, alarm, sound, TV and other low-voltage systems.
C-8Concrete
Concrete forms, placing and finishing: slabs, foundations, driveways, walkways and patios. Must carry workers' compensation even with no employees.
C-9Drywall
Hanging, taping and texturing gypsum wallboard.
C-10Electrical
Wiring, panels, lighting, EV chargers and any system that generates, carries or uses electricity, including solar electric systems and battery storage.
C-11Elevator
Elevators, dumbwaiters, wheelchair lifts and similar conveyances.
C-12Earthwork and Paving
Digging, grading, trenching and asphalt or other paving.
C-13Fencing
Fences, gates and similar barriers of wood, metal, vinyl or other materials.
C-15Flooring and Floor Covering
Wood, vinyl, carpet, laminate and other floor coverings.
C-16Fire Protection
Fire sprinkler and fire protection systems. A general contractor must hold C-16 or subcontract this work.
C-17Glazing
Glass, windows, mirrors, shower doors and storefront glazing.
C-20Warm-Air Heating, Ventilating and Air-Conditioning (HVAC)
Furnaces, air conditioners, ductwork and heat pumps, including heat pump water heaters. Must carry workers' compensation even with no employees.
C-21Building Moving/Demolition
Demolishing, raising, moving or removing structures and their foundations.
C-22Asbestos Abatement
Removing or containing asbestos-containing materials. Must carry workers' compensation even with no employees.
C-23Ornamental Metal
Decorative metal railings, gates, grilles and similar metal work.
C-27Landscaping
Planting, irrigation, hardscape, garden walls, decks and similar yard work tied to landscaping.
C-28Lock and Security Equipment
Locks, safes, access control and related security hardware.
C-29Masonry
Brick, block, stone and similar masonry work.
C-31Construction Zone Traffic Control
Traffic control devices and signage at work zones.
C-32Parking and Highway Improvement
Striping, wheel stops, signs and similar road and parking-lot improvements.
C-33Painting and Decorating
Painting, staining, wall coverings and related surface preparation.
C-34Pipeline
Pipelines for water, gas, sewage and other fluids, outside of buildings.
C-35Lathing and Plastering
Lath, plaster and stucco.
C-36Plumbing
Water, gas and drain piping, fixtures, water heaters (including heat pump water heaters), and solar water heating.
C-38Refrigeration
Refrigeration equipment and systems.
C-39Roofing
Roof coverings, roof repairs and waterproofing of roofs. Must carry workers' compensation even with no employees.
C-42Sanitation System
Septic tanks, leach lines and similar on-site sewage systems.
C-43Sheet Metal
Sheet metal work such as ducts, flashing, gutters and hoods.
C-45Sign
Signs and sign structures.
C-46Solar
Solar thermal and photovoltaic (PV) systems. Not for other building trades, and limits apply to adding battery storage.
C-47General Manufactured Housing
Installing manufactured homes, including manufactured ADUs built off site.
C-49Tree and Palm
Pruning, trimming and removing trees and palms (formerly D-49 Tree Service). Must carry workers' compensation even with no employees.
C-50Reinforcing Steel
Rebar and other steel reinforcement for concrete.
C-51Structural Steel
Structural steel framing and members.
C-53Swimming Pool
Pools and spas, including related equipment and solar pool heating.
C-54Ceramic and Mosaic Tile
Ceramic, porcelain, stone and mosaic tile.
C-55Water Conditioning
Water softeners, filters and treatment equipment.
C-57Well Drilling
Water wells. A general contractor must hold C-57 or subcontract this work.
C-60Welding
Welding work not covered by another classification.
C-61Limited Specialty
A group of narrower specialties listed as D subcategories, such as D-28 doors and gates, D-29 paperhanging, D-35 pool maintenance, D-41 siding and decking, D-52 window coverings and D-65 weatherization.

C-61 Limited Specialty (D subcategories)

D-03 Awnings · D-04 Central Vacuum Systems · D-06 Concrete-Related Services · D-10 Elevated Floors · D-12 Synthetic Products · D-16 Hardware, Locks and Safes · D-21 Machinery and Pumps · D-24 Metal Products · D-28 Doors, Gates and Activating Devices · D-29 Paperhanging · D-30 Pile Driving/Pressure Foundation Jacking · D-31 Pole Installation and Maintenance · D-34 Prefabricated Equipment · D-35 Pool and Spa Maintenance · D-38 Sand and Water Blasting · D-39 Scaffolding · D-40 Service Station Equipment and Maintenance · D-41 Siding and Decking · D-42 Non-Electrical Sign Installation · D-49 Tree Service (now C-49 Tree and Palm) · D-50 Suspended Ceilings · D-52 Window Coverings · D-53 Wood Tanks · D-56 Trenching · D-59 Hydroseed Spraying · D-62 Air and Water Balancing · D-63 Construction Cleanup · D-64 Non-specialized · D-65 Weatherization and Energy Conservation

The B general contractor rule

A B General Building contractor can take a job that's framing or carpentry, or one that needs at least two other unrelated trades. For a single-trade job, like only a roof or only electrical, the B contractor needs the specialty license or a licensed specialty subcontractor. Framing and carpentry don't count toward the two trades. B contractors can't contract for fire protection (C-16) or well drilling (C-57) without holding those licenses or subcontracting them.

B-2 Residential Remodeling

B-2 was created for remodels of existing wood-frame homes that use at least three unrelated trades in one contract, for example drywall, flooring and painting. A B-2 can't change load-bearing structure, and can't install, replace or extend electrical, plumbing or mechanical systems without the right license or a licensed subcontractor. Swapping fixtures as part of a three-trade job is allowed.

Heat pumps, solar and batteries

HVAC heat pumps fall under C-20. Heat pump water heaters fall under C-20 or C-36. An electrician (C-10) can upgrade the panel for the equipment but can't contract for the heat pump itself. Solar PV can be done by C-46 Solar or C-10 Electrical contractors, and by A and B contractors as part of their work. Battery storage is C-10 work. CSLB limits when a C-46 solar contractor can add a battery as part of a PV install. Those limits were amended in 2024 and were on hold as of CSLB's May 2025 guide.

Check a California contractor

Search any California contractor by name or license number to see the CSLB license status, classifications, bond, workers' comp, matched building permits and board discipline in one report. Public records, not a rating of workmanship.

Frequently asked questions

What is the difference between a B and a B-2 license in California?

A B General Building contractor can take projects with framing or carpentry, or two or more unrelated trades, including new construction and structural work. A B-2 Residential Remodeling contractor works on existing wood-frame homes, needs at least three unrelated trades per contract, and can't make structural changes or install new electrical, plumbing or mechanical systems on its own.

Can a general contractor do electrical or plumbing work in California?

A B contractor can include electrical or plumbing as part of a project with two or more unrelated trades. For an electrical-only or plumbing-only job, it needs the C-10 or C-36 license or must subcontract to someone who has it.

What license does a solar installer need in California?

C-46 Solar or C-10 Electrical. A and B contractors can also do solar as part of their work, according to CSLB's classification guide.

What does C-61 mean on a California license?

C-61 is Limited Specialty. It's always paired with a D subcategory, such as D-28 Doors and Gates or D-41 Siding and Decking, that shows the specific work allowed.

Sources

Written by HomeProFax in our own words from California Contractors State License Board (CSLB) publications. Last reviewed 2026-11-14. CSLB is the authority. Read the original publications below and confirm anything important with CSLB at 800-321-2752.

More California guides and tools

California homeowner hub · Look up a California contractor license · Los Angeles · San Diego · San Jose · San Francisco · Sacramento